Open Data Schema for Energy

Wheeling Transaction Envelope

Three wheeling models are active in South Africa: traditional (physical delivery on a single network), virtual (financial settlement across networks), and portfolio (multi-to-multi under a single arrangement). ODS-E provides a standard envelope for all three.

Context

The SAETA “Policy to Power” report identifies fragmented data exchange, manual reconciliation, and inconsistent treatment across networks as barriers to scaling wheeling (Actions 7, 8). It calls for “standardised and automated reconciliation and billing” and “modern digital systems for data exchange, energy accounting and financial settlement.”

These fields complement the existing wheeling_agent_id, seller_party_id, and buyer_party_id from the market context extensions.

Timeseries Fields

Field Type Description
wheeling_type enum: traditional, virtual, portfolio Wheeling model for this transaction
injection_point_id string Grid injection point identifier for the wheeling path
offtake_point_id string Grid offtake point identifier for the wheeling path
wheeling_status enum: provisional, confirmed, reconciled, disputed Reconciliation status of this wheeling record
wheeling_path_id string Reference to a registered wheeling path or schedule

Usage Notes

Example

{
  "timestamp": "2026-02-17T14:00:00+02:00",
  "kWh": 87.3,
  "error_type": "normal",
  "direction": "generation",
  "seller_party_id": "za-nersa:trader:ENPOWER-001",
  "buyer_party_id": "za-city-capetown:offtaker:METRO-4401",
  "wheeling_agent_id": "za-nersa:trader:ENPOWER-001",
  "network_operator_id": "za-eskom:network_operator:WC-01",
  "wheeling_type": "virtual",
  "injection_point_id": "NCAPE-SOLAR-GEN-12",
  "offtake_point_id": "CCT-DIST-MV-BELLVILLE-03",
  "wheeling_status": "confirmed",
  "wheeling_path_id": "WP-2026-ENPOWER-CCT-003",
  "loss_factor": 0.032,
  "contract_reference": "PPA-ENPOWER-CCT-2025-017"
}